Schneider GV2P16: GV2 motor protection circuit breaker, adjustable 9 … 14 A, with built-in short-circuit and overload protection and isolation.
A motor circuit breaker replaces fuses and a separate overload relay: it trips magnetically on short circuit and thermally on overload, and it can be locked off for maintenance.
See our Schneider Electric range.
Technical data
| Schneider reference | GV2P16 |
|---|---|
| Product or component type | Motor circuit breaker |
| Device application | Motor protection |
| Trip unit technology | Thermal-magnetic |
| Poles description | 3P |
| Network type | AC |
| Utilisation category | Category A conforming to IEC 60947-2; AC-3 conforming to IEC 60947-4-1; AC-3e conforming to IEC 60947-4-1 |
| Network frequency | 50/60 Hz conforming to IEC 60947-2 |
| Motor power kW | 5.5 kW at 400/415 V AC 50/60 Hz; 7.5 kW at 500 V AC 50/60 Hz; 9 kW at 690 V AC 50/60 Hz; 11 kW at 690 V AC 50/60 Hz |
| Breaking capacity | 100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2; 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Ics] rated service short-circuit breaking capacity | 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2; 100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 |
| Control type | Rotary handle |
| [In] rated current | 14 A |
| Thermal protection adjustment range | 9 … 14 A conforming to IEC 60947-2 |
| Magnetic tripping current | 253.4 A |
| [Ith] conventional free air thermal current | 14 A conforming to IEC 60947-2 |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Ui] rated insulation voltage | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947-2 |
| Phase failure sensitivity | Yes conforming to IEC 60947-4-1 |
| Suitability for isolation | Yes conforming to IEC 60947-1 |
| Dimensions (W x H x D) | 45 x 89 x 97 mm |
| Condition | New, original Schneider Electric |
Key characteristics (per Schneider)
- Motor circuit breaker
- TeSys Deca
- 3P
- 9 to 14A
- thermal magnetic
- screw clamp terminals
- rotary handle
Typical applications
- Motor branches with rated current 9 … 14 A
- Machine panels requiring a lockable isolator
- Fuseless motor starters with LC1D contactors
- Pumps, fans and small compressors
Compatibility and replacement
Accessories include front auxiliary contacts (GVAE11, GVAE20), side contacts (GVAN11), shunt and undervoltage releases and door-mounted handles. Check the data sheet for exact compatibility.
Frequently asked questions
Can I add auxiliary contacts?
Yes, front GVAE or side GVAN auxiliary contact blocks can be fitted.
Is the magnetic trip adjustable?
No. Only the thermal (overload) setting is adjustable; the magnetic trip is fixed at 253.4 A.
Can it isolate the motor for maintenance?
Yes, the GV2 has an isolating function and can be padlocked in the off position with the appropriate accessory.
What current range does it cover?
9 … 14 A, adjustable on the front dial.
How fast can you deliver, and is there a warranty?
Air shipping usually takes 5 to 7 days once the part is ready, to almost any country. Each part is new and original with a 1-year warranty. Message us on WhatsApp with the order number for a quotation.
Before you order
Compare the complete order number on the old unit with this page, including the suffix: in most ranges the last characters set the coil voltage, current range or version. If the label is worn, send us a photo and we will identify the part.
Every part RendatSP supplies is new and original, carries a 1-year warranty and ships worldwide by air in 5 to 7 days once ready (shipping, payment and warranty). Send us the order number and quantity on WhatsApp or through the inquiry form and we will quote the same working day. Agents in Saudi Arabia, Iraq, the UAE, Egypt, Oman, Libya, Morocco, Mauritania, Yemen, Algeria and Jordan.