Schneider GV2P06: GV2 motor protection circuit breaker, adjustable 1 … 1.6 A, with built-in short-circuit and overload protection and isolation.
Together with an LC1D contactor the GV2 makes a compact fuseless starter; Schneider offers combination blocks (GV2AF) to connect the breaker directly to the contactor.
See our Schneider Electric range.
Technical data
| Schneider reference | GV2P06 |
|---|---|
| Product or component type | Motor circuit breaker |
| Device application | Motor protection |
| Trip unit technology | Thermal-magnetic |
| Poles description | 3P |
| Network type | AC |
| Utilisation category | Category A conforming to IEC 60947-2; AC-3 conforming to IEC 60947-4-1; AC-3e conforming to IEC 60947-4-1 |
| Network frequency | 50/60 Hz conforming to IEC 60947-2 |
| Motor power kW | 0.37 kW at 400/415 V AC 50/60 Hz; 0.55 kW at 400/415 V AC 50/60 Hz; 0.37 kW at 500 V AC 50/60 Hz; 0.55 kW at 500 V AC 50/60 Hz; 0.75 kW at 690 V AC 50/60 Hz |
| Breaking capacity | 100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2; 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Ics] rated service short-circuit breaking capacity | 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2; 100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 |
| Control type | Rotary handle |
| [In] rated current | 1.6 A |
| Thermal protection adjustment range | 1 … 1.6 A conforming to IEC 60947-2 |
| Magnetic tripping current | 26.2 A |
| [Ith] conventional free air thermal current | 1.6 A conforming to IEC 60947-2 |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Ui] rated insulation voltage | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947-2 |
| Phase failure sensitivity | Yes conforming to IEC 60947-4-1 |
| Suitability for isolation | Yes conforming to IEC 60947-1 |
| Dimensions (W x H x D) | 45 x 89 x 97 mm |
| Condition | New, original Schneider Electric |
At a glance
- Motor circuit breaker
- TeSys Deca
- 3P
- 1 to 1.6A
- thermal magnetic
- screw clamp terminals
- rotary handle
Typical applications
- Replacement of a damaged GV2 breaker
- Fuseless motor starters with LC1D contactors
- Motor branches with rated current 1 … 1.6 A
- Pumps, fans and small compressors
Compatibility and replacement
Accessories include front auxiliary contacts (GVAE11, GVAE20), side contacts (GVAN11), shunt and undervoltage releases and door-mounted handles. Check the data sheet for exact compatibility.
Frequently asked questions
Is the magnetic trip adjustable?
No. Only the thermal (overload) setting is adjustable; the magnetic trip is fixed at 26.2 A.
What is its breaking capacity?
Per Schneider: 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2.
What current range does it cover?
1 … 1.6 A, adjustable on the front dial.
Can it isolate the motor for maintenance?
Yes, the GV2 has an isolating function and can be padlocked in the off position with the appropriate accessory.
How fast can you deliver, and is there a warranty?
Air shipping usually takes 5 to 7 days once the part is ready, to almost any country. Each part is new and original with a 1-year warranty. Message us on WhatsApp with the order number for a quotation.
Ordering tips
Send us the full order number from the label of the old part, or a clear photo of the label, together with the quantity you need. We check the number against the current manufacturer data before we quote and tell you if there is a newer replacement.
RendatSP ships from Yiwu, China, to factories worldwide; air delivery usually takes 5 to 7 days once the part is ready. The part is new and original with a 1-year warranty (shipping, payment and warranty). For a quotation, message us on WhatsApp with the order number and quantity. We also have agents in Saudi Arabia, Iraq, the UAE, Egypt, Oman, Libya, Morocco, Mauritania, Yemen, Algeria and Jordan.