The Schneider Electric EZC250N3125 is described by Schneider as: circuit breaker, EasyPact EZC250N, TMD, 125A, 3 poles 3d.
EasyPact EZC moulded case circuit breakers protect feeders and panels against overload and short circuit and are a standard choice for main and distribution breakers in machine panels and buildings.
See our Schneider Electric range.
Technical data
| Schneider reference | EZC250N3125 |
|---|---|
| Product or component type | Circuit breaker |
| Circuit breaker name | Easypact EZC250N |
| Device application | Distribution |
| Poles description | 3P |
| Protected poles description | 3t |
| Network type | AC; DC |
| Network frequency | 50/60 Hz |
| [In] rated current | 125 A at 40 °C |
| [Ui] rated insulation voltage | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947-2 |
| [Ue] rated operational voltage | 550 V AC 50/60 Hz conforming to IEC 60947-2; 250 V DC conforming to IEC 60947-2 |
| Breaking capacity code | N |
| Breaking capacity | 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2; 50 kA Icu at 110…130 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Ics] rated service breaking capacity | 10 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2; 25 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2; 10 kA at 125 V DC conforming to IEC 60947-2 |
| Suitability for isolation | Yes conforming to IEC 60947-2 |
| Utilisation category | Category A |
| Trip unit name | TM-D |
| Trip unit technology | Thermal-magnetic |
| Trip unit rating | 125 A at 50 °C |
| Protection type | Short-circuit protection; Overload protection |
| Dimensions (W x H x D) | 105 x 165 x 60 mm |
| Condition | New, original Schneider Electric |
Key characteristics (per Schneider)
- circuit breaker
- EasyPact EZC250N
- TMD
- 125A
- 3 poles 3d
Typical applications
- Feeder protection in distribution boards
- Main switch of machine panels
- Replacement of a tripped or damaged MCCB
- Motor feeders with suitable rating
Compatibility and replacement
Compare the frame (EZC100 or EZC250), number of poles, rated current and breaking capacity with the old breaker.
Frequently asked questions
Is the trip unit adjustable?
See the Schneider table: EZC100 breakers have fixed thermal-magnetic trip units; adjustability depends on the frame.
What does the breaking capacity mean?
It is the highest short-circuit current the breaker can interrupt safely at the stated voltage; it must be at least the prospective short-circuit current at the installation point.
Is it new and original?
Yes. We supply new, original parts in the manufacturer packaging, with a 1-year warranty.
Can I get a datasheet?
The official manufacturer datasheet is the source of the technical data above; we can send the PDF with the quotation on request.
Do you ship to my country, and what is the warranty?
Yes. RendatSP ships worldwide from Yiwu, China, by air in 5 to 7 days once the part is ready, and every part carries a 1-year warranty. Send the order number and quantity on WhatsApp and we will reply with a quotation.
Before you order
Compare the complete order number on the old unit with this page, including the suffix: in most ranges the last characters set the coil voltage, current range or version. If the label is worn, send us a photo and we will identify the part.
RendatSP ships from Yiwu, China, to factories worldwide; air delivery usually takes 5 to 7 days once the part is ready. The part is new and original with a 1-year warranty (shipping, payment and warranty). For a quotation, message us on WhatsApp with the order number and quantity. We also have agents in Saudi Arabia, Iraq, the UAE, Egypt, Oman, Libya, Morocco, Mauritania, Yemen, Algeria and Jordan.