The Schneider Electric EZC250H3200 is described by Schneider as: circuit breaker, EasyPact EZC250H, TMD, 200A, 3 poles 3d.
The EZC100 and EZC250 frames cover ratings up to 100 A and 250 A; replacing a breaker with the same frame keeps the panel cut-out and busbar connections.
See our Schneider Electric range.
Technical data
| Schneider reference | EZC250H3200 |
|---|---|
| Product or component type | Circuit breaker |
| Circuit breaker name | Easypact EZC250H |
| Device application | Distribution |
| Poles description | 3P |
| Protected poles description | 3t |
| Network type | AC; DC |
| Network frequency | 50/60 Hz |
| [In] rated current | 200 A at 40 °C |
| [Ui] rated insulation voltage | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947-2 |
| [Ue] rated operational voltage | 550 V AC 50/60 Hz conforming to IEC 60947-2; 250 V DC conforming to IEC 60947-2 |
| Breaking capacity code | H |
| Breaking capacity | 10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2; 25 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2; 30 kA Icu at 125 V DC 1P conforming to IEC 60947-2 |
| [Ics] rated service breaking capacity | 5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2; 15 kA at 125 V DC conforming to IEC 60947-2; 15 kA at 250 V DC conforming to IEC 60947-2 |
| Suitability for isolation | Yes conforming to IEC 60947-2 |
| Utilisation category | Category A |
| Trip unit name | TM-D |
| Trip unit technology | Thermal-magnetic |
| Trip unit rating | 200 A at 50 °C |
| Protection type | Overload protection; Short-circuit protection |
| Dimensions (W x H x D) | 105 x 165 x 60 mm |
| Condition | New, original Schneider Electric |
Main characteristics
- circuit breaker
- EasyPact EZC250H
- TMD
- 200A
- 3 poles 3d
Typical applications
- Motor feeders with suitable rating
- Feeder protection in distribution boards
- Main switch of machine panels
- Replacement of a tripped or damaged MCCB
Compatibility and replacement
Compare the frame (EZC100 or EZC250), number of poles, rated current and breaking capacity with the old breaker.
Frequently asked questions
What does the breaking capacity mean?
It is the highest short-circuit current the breaker can interrupt safely at the stated voltage; it must be at least the prospective short-circuit current at the installation point.
Can you help me identify the right replacement?
Yes. Send us a photo of the label of the old part, or its full order number, and we will confirm the exact match or the official successor before quoting.
Can I get a datasheet?
The official manufacturer datasheet is the source of the technical data above; we can send the PDF with the quotation on request.
Is the trip unit adjustable?
See the Schneider table: EZC100 breakers have fixed thermal-magnetic trip units; adjustability depends on the frame.
Do you ship to my country, and what is the warranty?
Yes. RendatSP ships worldwide from Yiwu, China, by air in 5 to 7 days once the part is ready, and every part carries a 1-year warranty. Send the order number and quantity on WhatsApp and we will reply with a quotation.
How to order
Message us the order number and quantity. For breakdowns, tell us the delivery address and we will offer the fastest shipping option. If the exact part is discontinued, we confirm the official successor before quoting.
RendatSP ships from Yiwu, China, to factories worldwide; air delivery usually takes 5 to 7 days once the part is ready. The part is new and original with a 1-year warranty (shipping, payment and warranty). For a quotation, message us on WhatsApp with the order number and quantity. We also have agents in Saudi Arabia, Iraq, the UAE, Egypt, Oman, Libya, Morocco, Mauritania, Yemen, Algeria and Jordan.