Danfoss order code 060G1609 is a pressure transmitter from the MBS 3000 range: MBS 3000 Pressure Transmitter 0-35 bar Sealed Gauge, Ratiometric, G 1/4, DIN Plug.
Pressure transmitters are the eyes of a pump or compressor control loop: a drive or PLC uses the signal to hold the set pressure, so a failed transmitter stops the system or makes it hunt; the replacement must match range, signal and connections.
More Danfoss drives, sensors, switches and valves: Danfoss range.
Technical data
| Danfoss order code | 060G1609 |
|---|---|
| Net weight | 0.157 Kilogram |
| Type | MBS 3050 |
| + output | Pin 3 |
| + supply | Pin 1 |
| – common | Pin 2 |
| Accuracy, max. (±FS%) | 1 % |
| Accuracy, typical (±FS%) | 0.3 % |
| Ambient temperature range (°C) | -40 °C to 85 °C |
| Approval | ATEX C UL US UL Recognized CE |
| Approval comments | ATEX Ex ec IIA T4 Gc |
| Compensated temperature range (°C) | 0 °C to 80 °C |
| Electrical connector gender | Male and Female |
| Electrical connection | Angular connector |
| Electrical connection size | Pg 9 |
| Electrical connection standard | EN 175301-803-A |
| Enclosure rating IP | IP65 |
| Identical product | 060G4177 |
| Medium temperature range (°C) | -40 °C to 85 °C |
| Non-linearity BFSL (±FS%) | 0.2 % |
| Output signal | Ratio metric |
| Overload pressure max. (bar) | 100 bar |
| Pressure connection HEX (mm) | 27 mm |
| Pressure connection notes | Special |
| Pressure connection size | 1/4 |
| Pressure connection standard | DIN 3852-G |
| Pressure connection type | G |
| Pressure Male/Female | Male |
| Pressure range (bar) | 0 bar to 35 bar |
| Pressure reference | Sealed gauge |
Configuration and key data (per Danfoss)
- Pressure reference: Sealed gauge
- Output signal: Ratio metric
- Electrical connection: Angular connector
- Pressure connection type: G
- Pressure connection size: 1/4
- Specification key: MBS 3050-2536-A1FB04-4
Typical applications
- Replacement of a failed transmitter
- Water treatment
- Hydraulics and lubrication systems
- Compressors and air systems
- Pump and booster-set pressure control
Compatibility and replacement
Order with the complete Danfoss code 060G1609; in Danfoss product codes the variant digits select the voltage, range, connection or option set, so a part with a different code may not be a direct replacement.
The values in the table come from the official Danfoss product data; if your old unit shows different values, send us a photo of its label and we will check it.
Before you replace it
- Output signal (4-20 mA, voltage or ratiometric)
- Pressure range and reference (gauge, sealed gauge or absolute)
- Electrical connection (plug or cable)
Frequently asked questions
How is it connected electrically?
Angular connector, according to the Danfoss product data.
What output signal does it give?
Ratio metric, according to the Danfoss product data.
What is the protection rating?
IP65, according to the Danfoss product data.
What is the pressure connection?
G, according to the Danfoss product data.
What pressure range does it measure?
0 bar to 35 bar, according to the Danfoss product data.
Do you supply larger quantities for projects?
Yes. For panel builders, OEMs and plant projects we quote complete lists; send the bill of materials on WhatsApp or through the inquiry form.
Do you ship to my country, and what is the warranty?
Yes. RendatSP ships worldwide from Yiwu, China, by air in 5 to 7 days once the part is ready, and every part carries a 1-year warranty. Send the order number and quantity on WhatsApp and we will reply with a quotation.
Before you order
Compare the complete order number on the old unit with this page, including the suffix: in most ranges the last characters set the coil voltage, current range or version. If the label is worn, send us a photo and we will identify the part.
Every part RendatSP supplies is new and original, carries a 1-year warranty and ships worldwide by air in 5 to 7 days once ready (shipping, payment and warranty). Send us the order number and quantity on WhatsApp or through the inquiry form and we will quote the same working day. Agents in Saudi Arabia, Iraq, the UAE, Egypt, Oman, Libya, Morocco, Mauritania, Yemen, Algeria and Jordan.