The Schneider Electric GV3P25 is a TeSys GV3 motor circuit breaker with thermal-magnetic protection, thermal setting 17 … 25 A, magnetic tripping at 350 A.
The GV3 covers the larger motor ratings above the GV2 range and is combined with TeSys Deca LC1D contactors to build fuseless starters.
See our Schneider Electric range.
Technical data
| Schneider reference | GV3P25 |
|---|---|
| Product or component type | Motor circuit breaker |
| Device application | Motor protection |
| Trip unit technology | Thermal-magnetic |
| Poles description | 3P |
| Network type | AC |
| Utilisation category | Category A conforming to IEC 60947-2; AC-3 conforming to IEC 60947-4-1 |
| Network frequency | 50/60 Hz conforming to IEC 60947-2 |
| Motor power kW | 11 kW at 400/415 V AC 50/60 Hz; 15 kW at 500 V AC 50/60 Hz; 18.5 kW at 690 V AC 50/60 Hz |
| Breaking capacity | 100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2; 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Ics] rated service short-circuit breaking capacity | 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2; 100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 |
| Control type | Rotary handle |
| [In] rated current | 25 A |
| Thermal protection adjustment range | 17 … 25 A conforming to IEC 60947-2 |
| Magnetic tripping current | 350 A |
| [Ith] conventional free air thermal current | 25 A conforming to IEC 60947-2 |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Ui] rated insulation voltage | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947-2 |
| Phase failure sensitivity | Yes conforming to IEC 60947-4-1 |
| Suitability for isolation | Yes conforming to IEC 60947-1 |
| Dimensions (W x H x D) | 55 x 132 x 136 mm |
| Condition | New, original Schneider Electric |
Key characteristics (per Schneider)
- Motor circuit breaker
- TeSys Deca frame 3
- 3P
- 17-25A
- thermal magnetic
- EverLink terminals
Typical applications
- Pumps, fans and compressors
- Motor branches with rated current 17 … 25 A
- Machine panels requiring a lockable isolator
- Replacement of a damaged GV3 breaker
Compatibility and replacement
Auxiliary contacts and other accessories for the GV3 are listed by Schneider in the data sheet; check the compatibility row before ordering accessories.
Frequently asked questions
What current range does it cover?
17 … 25 A, adjustable on the front dial.
Is the magnetic trip adjustable?
No. Only the thermal (overload) setting is adjustable; the magnetic trip is fixed at 350 A.
What is its breaking capacity?
Per Schneider: 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2.
Is it the same as a GV2?
No. The GV3 is a larger frame for higher currents; GV2 and GV3 breakers are not interchangeable in the panel layout.
How fast can you deliver, and is there a warranty?
Air shipping usually takes 5 to 7 days once the part is ready, to almost any country. Each part is new and original with a 1-year warranty. Message us on WhatsApp with the order number for a quotation.
Ordering tips
Send us the full order number from the label of the old part, or a clear photo of the label, together with the quantity you need. We check the number against the current manufacturer data before we quote and tell you if there is a newer replacement.
RendatSP ships from Yiwu, China, to factories worldwide; air delivery usually takes 5 to 7 days once the part is ready. The part is new and original with a 1-year warranty (shipping, payment and warranty). For a quotation, message us on WhatsApp with the order number and quantity. We also have agents in Saudi Arabia, Iraq, the UAE, Egypt, Oman, Libya, Morocco, Mauritania, Yemen, Algeria and Jordan.