Reference A9F74110 is a genuine Schneider Electric product from the Acti9 breakers and accessories range: Miniature circuit breaker (MCB), Acti9 iC60N, 1P, 10A, C curve, 6000A (IEC/EN 60898-1), 10kA (IEC/EN 60947-2).
Acti9 miniature circuit breakers protect cables and loads against overload and short circuit in distribution and control panels.
See our Schneider Electric range.
Technical data
| Schneider reference | A9F74110 |
|---|---|
| Product or component type | Miniature circuit-breaker |
| Device application | Distribution |
| Poles description | 1P |
| Number of protected poles | 1 |
| [In] rated current | 10 A |
| Network type | DC; AC |
| Trip unit technology | Thermal-magnetic |
| Curve code | C |
| Product compatibility | Vigi iC60 single terminal add-on residual current device 25/40/63 A; Quick Vigi iC60 single terminal add-on residual current device 25/40 A |
| Utilisation category | Category A conforming to EN/IEC 60947-2 |
| Suitability for isolation | Yes conforming to EN/IEC 60898-1; Yes conforming to EN/IEC 60947-2 |
| Network frequency | 50/60 Hz |
| [Ue] rated operational voltage | 12…60 V AC 50/60 Hz; 100…133 V AC 50/60 Hz; 220…240 V AC 50/60 Hz; 12…60 V DC; 60…72 V DC |
| Magnetic tripping limit | 8 x In +/- 20 % |
| Breaking capacity | 36 kA Icu at 12…60 V AC 50/60 Hz conforming to EN/IEC 60947-2; 20 kA Icu at 100…133 V AC 50/60 Hz conforming to EN/IEC 60947-2 |
| [Ics] rated service breaking capacity | 27 kA 75 % x Icu at 12…60 V AC 50/60 Hz conforming to EN/IEC 60947-2; 15 kA 75 % x Icu at 100…133 V AC 50/60 Hz conforming to EN/IEC 60947-2 |
| Limitation class | 3 conforming to EN/IEC 60898-1 |
| [Ui] rated insulation voltage | 500 V AC 50/60 Hz conforming to EN/IEC 60947-2 |
| Contact position indicator | Yes |
| Control type | Toggle |
| Dimensions (W x H x D) | 18 x 85 x 78.5 mm |
| Condition | New, original Schneider Electric |
At a glance
- Miniature circuit breaker (MCB)
- Acti9 iC60N
- 1P
- 10A
- C curve
- 6000A (IEC/EN 60898-1)
- 10kA (IEC/EN 60947-2)
Typical applications
- Lighting and socket circuits
- Control panel protection
- Replacement of a tripped or damaged breaker
Compatibility and replacement
Check poles, rating, curve and breaking capacity.
Frequently asked questions
Can you help me identify the right replacement?
Yes. Send us a photo of the label of the old part, or its full order number, and we will confirm the exact match or the official successor before quoting.
Do you supply larger quantities for projects?
Yes. For panel builders and plant projects we quote complete lists; send the bill of materials on WhatsApp or through the inquiry form.
Which curve is it?
See the tripping curve in the table.
Can I get a price and delivery time?
Prices are quoted on request. Send the order number, quantity and delivery country on WhatsApp and we will reply with price and delivery time; air shipping is usually 5 to 7 days once ready, with a 1-year warranty.
Before you order
Compare the complete order number on the old unit with this page, including the suffix: in most ranges the last characters set the coil voltage, current range or version. If the label is worn, send us a photo and we will identify the part.
RendatSP ships from Yiwu, China, to factories worldwide; air delivery usually takes 5 to 7 days once the part is ready. The part is new and original with a 1-year warranty (shipping, payment and warranty). For a quotation, message us on WhatsApp with the order number and quantity. We also have agents in Saudi Arabia, Iraq, the UAE, Egypt, Oman, Libya, Morocco, Mauritania, Yemen, Algeria and Jordan.