Schneider A9R11263 Acti9 iID RCCB 2P 63A 30 mA Type AC

تواصل معنا للسعر

Genuine Schneider Electric A9R11263: Residual current circuit breaker (RCCB), Acti9 iID, 2P, 63A, AC type, 30mA. New original Schneider, supplied by RendatSP with worldwide shipping.

رمز المنتج: A9R11263 التصنيفات: , العلامة التجارية:
1اطلب عرض سعر3

1تحتاج هذه القطعة؟3 A9R11263

1أرسل لنا رقم القطعة والكمية، وفريقنا الناطق بالعربية والإنجليزية يرد عليك بالسعر وحالة التوفر ومدة التوريد، عادةً خلال ساعات.3
1الكمية3
    1قطع أصلية بتغليف المصنع فقط3 1عرض سعر خلال ساعات، بالعربية أو الإنجليزية3 1شحن جوي أو بحري لكل دول العالم: الدول العربية وأفريقيا والأمريكتين وأوروبا3

1أو راسلنا على3 info@rendatsp.com · +86 181 5871 1787

The Schneider Electric A9R11263 is an Acti9 iID residual current circuit breaker (RCCB), 2P, 63A, 30 mA sensitivity, Type AC.

Press the test button regularly to check the mechanism. Schneider lists the tripping technology as: Voltage independent.

See our Schneider Electric range.

Technical data

Schneider reference A9R11263
Product or component type Residual current circuit breaker (RCCB)
Poles description 2P
Neutral position Left
[In] rated current 63 A
Network type AC
Earth-leakage sensitivity 30 mA
Earth-leakage protection time delay Instantaneous
Earth-leakage protection class Type AC
Device location in system Outgoer
Network frequency 50/60 Hz
[Ue] rated operational voltage 230…240 V AC 50/60 Hz
Residual current tripping technology Voltage independent
Rated breaking and making capacity Idm 1500 A; Im 1500 A
Rated conditional short-circuit current 10 kA
[Ui] rated insulation voltage 500 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage 6 kV
Contact position indicator Yes
Width 36 mm
Tightening torque 3.5 N.m top or bottom
Electromagnetic compatibility 8/20 µs impulse withstand, 250 A conforming to EN/IEC 61008-1
Dimensions (W x H x D) 36 x 85 x 69 mm
Condition New, original Schneider Electric

Key characteristics (per Schneider)

  • Residual current circuit breaker (RCCB)
  • Acti9 iID
  • 2P
  • 63A
  • AC type
  • 30mA

Typical applications

  • Replacement of a faulty RCCB
  • Incoming device of sub-distribution boards
  • Earth-leakage protection of socket and lighting circuits
  • Protection of personnel in workshops and plants

Compatibility and replacement

Match poles (2P), rated current (63A), sensitivity (30 mA) and class (Type AC). Combine with suitable Acti9 circuit breakers for overload and short-circuit protection.

Frequently asked questions

Which voltage is it for?

230…240 V AC 50/60 Hz per Schneider.

Does it protect against short circuits?

No. An RCCB only detects earth leakage; use it together with circuit breakers. Schneider gives a rated conditional short-circuit current of 10 kA.

How often should I press the test button?

Follow local regulations; many installers test RCCBs every few months.

What sensitivity does it have?

30 mA, Type AC, per Schneider.

How fast can you deliver, and is there a warranty?

Air shipping usually takes 5 to 7 days once the part is ready, to almost any country. Each part is new and original with a 1-year warranty. Message us on WhatsApp with the order number for a quotation.

How to order

Message us the order number and quantity. For breakdowns, tell us the delivery address and we will offer the fastest shipping option. If the exact part is discontinued, we confirm the official successor before quoting.

Every part RendatSP supplies is new and original, carries a 1-year warranty and ships worldwide by air in 5 to 7 days once ready (shipping, payment and warranty). Send us the order number and quantity on WhatsApp or through the inquiry form and we will quote the same working day. Agents in Saudi Arabia, Iraq, the UAE, Egypt, Oman, Libya, Morocco, Mauritania, Yemen, Algeria and Jordan.