The Delta DVP40ES200T is a DVP-ES2 series programmable logic controller with 40 total input and output points (24 inputs and 16 outputs), transistor output, npn sinking and a 100-240 V AC supply. The ES2 is the standard slim PLC of the DVP family and the usual choice for general machine control.
Technical Specifications
| Brand | Delta Electronics |
|---|---|
| Series | DVP-ES2 |
| Model number | DVP40ES200T |
| Total input and output points | 40 |
| Digital inputs | 24 |
| Digital outputs | 16 |
| Output type | Transistor output, NPN sinking |
| Power supply | 100-240 V AC |
| Program capacity | 16k steps |
| Data registers | 10k words |
| Execution speed | 0.35 microseconds per LD, 3.4 microseconds per MOV |
| High speed counters | 2 points at 100 kHz and 6 points at 10 kHz |
| High speed pulse output | Up to 100 kHz |
| Communication ports | 1 x RS-232 and 2 x RS-485, Modbus ASCII and RTU, master and slave |
| Maximum expansion | 480 input and output points |
| Programming software | Delta WPLSoft / ISPSoft |
Key Features
- 16k program steps and 10k words of data register
- 0.35 microseconds per LD instruction
- Two high speed counters at 100 kHz and six at 10 kHz
- Pulse output up to 100 kHz
- One RS-232 and two RS-485 ports, Modbus ASCII and RTU, master and slave
- Expandable to 480 input and output points
Typical Applications
- General machine control and sequencing
- Conveyor and material handling control
- Packaging machinery
- Water treatment and pumping stations
- HVAC and building plant control
- Small production line automation
Frequently Asked Questions
What is the difference between the 200 and 211 in a DVP-ES2 part number?
It is the power supply. 200 means a 100 to 240 V AC supply and 211 means a 24 V DC supply. The rest of the part number reads the same way.
Can DVP40ES200T control a servo or stepper?
Yes. The ES2 transistor output models give pulse output up to 100 kHz, which suits slower positioning axes. For faster motion choose the DVP-EH3 T3, which reaches 200 kHz.
How many points can DVP40ES200T expand to?
Up to 480 input and output points with DVP expansion modules.
What does the part number DVP40ES200T mean?
DVP is the series, 40 is the total number of input and output points, ES2 is the series code, 200 is the power supply code and T is the output type.
Ordering and Delivery
RendatSP supplies this item to factories, machine builders and maintenance teams across the Middle East and Africa. Send us the model number and the quantity you need and we will come back with price, lead time and shipping to your country. Technical help with selection and replacement is included at no charge.