Delta VFD7A5MS21ANSAA MS300 Series VFD 1.5 kW 200-240 single phase

Delta MS300 VFD, 1.5 kW, 200-240 V single-phase, 7.5 A output, built-in brake chopper and STO.

SKU: VFD7A5MS21ANSAA Categories: ,

The Delta VFD7A5MS21ANSAA is an MS300 series variable frequency drive rated for a 1.5 kW (2 HP) motor on a 200-240 V single-phase supply. The MS300 is Delta’s current compact general purpose drive, with sensorless vector control, a built-in brake chopper on every frame and Safe Torque Off as standard.

Technical Specifications

Brand Delta Electronics
Series MS300
Model number VFD7A5MS21ANSAA
Rated motor power 1.5 kW (2 HP)
Input voltage 200-240 V single-phase, 50/60 Hz
Rated output current 7.5 A
Rated input current 17.9 A
Frame size C
Control method V/F, SVC, FOC sensorless vector, PM SVC
Output frequency 0 to 599 Hz
Carrier frequency 2 to 15 kHz, default 4 kHz
Overload capacity Heavy duty 150% for 60 s, 200% for 3 s
Built-in EMC filter No (filtered version available on request)
Built-in brake chopper Yes
Safety function STO, SIL2 / PLd
Communication RS-485 Modbus RTU (RJ45), one option card slot
Enclosure IP20 / NEMA 1
Keypad KPMS-LE01 standard LED keypad

Key Features

  • Sensorless vector control (FOC) plus V/F and SVC modes, with permanent magnet motor control
  • Built-in brake chopper on every frame size
  • Built-in Safe Torque Off (STO) certified to SIL2 / PLd
  • Built-in RS-485 Modbus RTU over RJ45, plus one option card slot for CANopen, PROFIBUS DP, DeviceNet, EtherNet/IP, PROFINET or EtherCAT
  • Heavy duty overload 150% for 60 seconds and 200% for 3 seconds
  • Side-by-side installation and removable, coated control board

Typical Applications

  • Machine tools and small CNC retrofits
  • Conveyors and material handling
  • Pumps and fans
  • Packaging and labelling machinery
  • Textile and printing machinery
  • Food processing equipment

Frequently Asked Questions

Does VFD7A5MS21ANSAA include a built-in EMC filter?

No. The N in this model code means no built-in EMC filter. Delta also builds a filtered version of the same rating, with an F in place of the N. Tell us which one you need and we will quote the correct part number.

What motor size does VFD7A5MS21ANSAA drive?

It is rated for a 1.5 kW (2 HP) three-phase induction motor, with a rated output current of 7.5 A.

Can VFD7A5MS21ANSAA replace an older Delta VFD-M, VFD-L, VFD-S or VFD-B drive?

Yes. Delta recommends the MS300 as the replacement for the discontinued VFD-M, VFD-L and VFD-S series and for the smaller VFD-B ratings. Match the motor current rather than the old model number when you select the replacement.

Which fieldbus options are available for VFD7A5MS21ANSAA?

RS-485 Modbus RTU is built in. The option card slot accepts CANopen, PROFIBUS DP, DeviceNet, EtherNet/IP, PROFINET and EtherCAT cards.

Ordering and Delivery

RendatSP supplies this item to factories, machine builders and maintenance teams across the Middle East and Africa. Send us the model number and the quantity you need and we will come back with price, lead time and shipping to your country. Technical help with selection and replacement is included at no charge.

Scroll to Top